Main Feature
- IP65-rated enclosure
- 6.5 kW pure sine wave output
- 48 V battery input
- Up to 9 kW PV input power
- Wi-Fi remote monitoring
- Parallel capability: up to six units
Product Details

IP65-rated enclosure
An IP65-rated enclosure houses the GS 6.5 kW hybrid inverter for protection-conscious equipment selection.

6.5 kW pure sine wave output
GS-652048-902A delivers 6.5 kW pure sine wave output at 230 VAC ±5%, with adjustable 50/60 Hz frequency.

Up to 9 kW PV input power
GS supports up to 9 kW PV input within its 85–450 V operating range; the open-circuit limit is 500 V.

48 V battery system
GS uses a 48 V battery system, with 120 A charging and 125 A discharging limits; combined PV/grid charging is 120 A.

Wi-Fi remote monitoring
Wi-Fi remote monitoring provides access to GS operating information beyond the front-panel LCD.

Parallel capability up to six units
Up to six GS units can operate in parallel, with phase arrangement and equipment matched to the configuration.
Technical specification
Download| MODEL | GS-652048-902A |
|---|---|
| Inverter Mode | |
| Rated Output Power | 6500VA/6500W |
| Rated DC Input Voltage | 48V |
| Maximum DC Charging/discharging Current | 120A/125A |
| Output Voltage Waveform | pure sine wave |
| Rated Output Voltage | 230Vac±5% |
| Rated Output Frequency | 50±0.3Hz/60±0.3Hz(Adjustable) |
| Parallel Capability | up to 6 units |
| Mains Mode | |
| Rated Output Power | 6500VA/6500W |
| Rated DC Input Voltage | 48V |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Low Voltage Disconnect Low | 230Vac |
| Reconnect After Voltage Loss | 90Vac±3V(For Home Appliances)/170Vac±3V(For Computers) |
| Mains Mode | 100Vac±3V(For HomeAppliances)/180Vac±3V(For Computers) |
| Input Voltage Range | 90-280Vac |
| Maximum Grid Charging Current | 120A |
| High Line Voltage Disconnection | 280Vac±3V |
| High Line Voltage Reconnection | 270Vac±3V |
| Maximum AC Input Voltage | 280Vac±3V |
| Maximum Grid Charging Current | 120A |
| Rated Input Frequency | 50Hz/60Hz (Auto detection) |
| Photovoltaic Input | |
| Maximum Open Circuit Voltage | 500V |
| Photovoltaic Voltage Range | 85-450V |
| Maximum Input Power | 9000W |
| Maximum Solar Charging Current | 120A |
| Maximum Charging Current (photovoltaic+grid) | 120A |
| Maximum Input Current | 27A |
| Minimum Starting Voltage | 75V |
| General Specifications | |
| Operating Temperature | -10°C~55°C |
| Storage Temperature Range | -15°C~60°C |
| Product Dimensions (length*width*height)mm | 632*400*196 |
| Packaging Dimensions (length*width*height)mm | 715*485*270 |
Why We Recommend the GS Inverter

Bring more solar-array capacity into your next 6.5 kW inverter installation. The GS accepts up to 9 kW of PV input and pairs it with 6.5 kW of pure sine wave output and a 48 V battery system. For us, that is a compelling reason to choose GS: its solar-input allowance gives you room to design the PV side beyond the inverter's AC output rating, within the specified PV voltage and current limits.
The GS also gives you two benefits customers can readily understand: an IP65-rated enclosure and Wi-Fi access to operating information without standing at the front panel. Together, they make enclosure protection and remote visibility part of your offer—not just another number on the specification sheet. We recommend the GS for buyers who want those features alongside substantial PV input capacity in one hybrid inverter.
FAQS
Which GS model, power rating and battery voltage does this page cover?
This page covers the GS-652048-902A, rated at 6500VA/6500W with a 48 V DC battery input and 230Vac ±5% pure sine wave output. It describes one 6.5 kW model, not a range of GS power ratings. Ask SNADI for the matching GS documentation and battery compatibility information for your order.
Does IP65 mean the GS can be installed anywhere outdoors?
No. IP65 is an enclosure protection rating, not approval for unrestricted outdoor placement or immersion. Obtain the installation requirements for the exact GS model before choosing a location, including any shelter, ventilation and clearance requirements.
What PV array limits should I check for the GS-652048-902A?
The GS lists 9000 W maximum PV input power, an 85–450 V photovoltaic voltage range, 500 V maximum open-circuit voltage, 27 A maximum input current and 75 V minimum starting voltage. Check the proposed array against all of these limits. Ask SNADI for the model-specific input configuration and string-connection documentation before finalising the array layout.
Can GS inverters operate in parallel or in a three-phase arrangement?
The GS has parallel capability of up to six units, with three-phase parallel operation listed as a multi-unit configuration. This does not make an individual GS unit a three-phase inverter. Request the GS parallel configuration documents to establish the unit arrangement, accessories and battery requirements for the installation.
What should I confirm before using a generator with the GS inverter?
Provide the generator specification, local AC supply and proposed switching arrangement for the GS-652048-902A. Ask SNADI to confirm the permitted connection diagram and any required switching equipment before specifying the installation. Confirm the interface against the applicable GS documentation for the order.