Main Feature
- Built-in 1 or 2 MPPT, model-dependent
- Up to six units in parallel on B models
- Off-grid and grid-connected operation
- Battery-free operation
- Detachable dust cover
- Optional Wi-Fi remote monitoring
Product Details

Built-in MPPT solar charging
Built-in solar charging uses one or two MPPT trackers, depending on the AS model.

Parallel expansion on B models
AS B models support up to six inverters in parallel. Choose an A model for stand-alone operation.

120 V and split-phase choices
Choose 3.6 kW or 6.5 kW models for 120 V output, or 7.2 kW or 12 kW models for 120/240 V split-phase output.

Solar power with or without storage
Run on available solar and utility power without a battery, or use lead-acid or lithium storage matched to your AS model.

Detachable dust cover
The AS has a detachable dust cover and forced-air cooling. Adjustable fan speed helps manage heat.

Optional Wi-Fi monitoring
Optional Wi-Fi lets you check operation remotely. USB and RS485 provide additional communication options.
Technical specification
Download| MODEL | AS362048-M80-A | AS362048-M80-B | AS652048-M150-A | AS652048-M150-B | AS722048-M150-A | AS722048-M150-B | AS123048-M200-A | AS123048-M200-B |
|---|---|---|---|---|---|---|---|---|
| Parallel Mode (function reserved) | ||||||||
| Allow Quantity | -A None/-B 1~6 | |||||||
| Mains Mode | ||||||||
| Nominal Input Voltage | 120VAC±5% | 120VAC(L1/N, L2/N)/240VAC(L1/L2) | ||||||
| Input Voltage Range | (90~140VAC)±2% | (85~140VAC)±2% | ||||||
| Frequency | 50/60Hz(Auto Detect) | |||||||
| Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz); 57±0.3Hz~65±0.3Hz(60Hz) | |||||||
| Max. Efficiency | >95% | |||||||
| Conversion Time (bypass and inverter) | 10ms(Typical Value) | |||||||
| Max. Bypass Overload Current | 40A | 60A | 2pole, 50A/50A(L1/L2) | 2P,63A/63A(L1/L2) | ||||
| Inverter Mode | ||||||||
| Output Voltage Waveform | Pure Sine Wave | |||||||
| Nominal Output Power | 3600VA/3600W | 6500VA/6500W | Split phase:7200VA Single phase:6000VA | Split phase:12000VA/12000W Single phase:7200VA/7200W(limited by the wiring terminals) | ||||
| Power Factor | 1 | |||||||
| Nominal Output Voltage | 120VAC | 120VAC(L1/N,L2/N)/240VAC(L1/L2) | ||||||
| Output Frequency Range | 50±0.3Hz/60±0.3Hz | |||||||
| Max. Efficiency | >91% | |||||||
| Overload Protection | (102%<load<125%)±10%: report error, turn off the output after 5 minutes (125%<load<150%)±10%: report error, turn off the output after 10 seconds load>150%±10%: report error, turn off the output after 5 seconds | (102%<load<110%)±5%: report error and turn off the output after 5 minutes (110%<load<125%)±5%: report error and turn off the output after 10 seconds load>125%±5%: report error and turn off the output after 5 seconds | ||||||
| Peak Power | 7200VA | 12000VA | Split phase:10800VA Single phase:10800VA | Split phase:18000VA Single phase:18000VA | ||||
| Load Motor Capability | 2HP | 5HP | 4HP | 6HP | ||||
| Nominal Battery Input Voltage | 48V(Min. starting voltage 44V) | 51.2V(Minimum starting voltage 44V) | ||||||
| Battery Voltage Range | 40.0~60Vdc±0.6Vdc(Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery...LCD screen can be set) | 40.0~58.6Vdc±0.6Vdc(Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery...settable on LCD screen) | ||||||
| Save Power Mode | Loads 25W | |||||||
| Mains Charge | ||||||||
| Battery Type | Lead-acid or lithium batteries | |||||||
| Max. Charge Current (configurable) | 40A | 120A | 160A | |||||
| Charge Voltage Range | 40~60VDC | 40~58.6VDC | ||||||
| Solar Charge | ||||||||
| Max. PV Open Circuit Voltage | 300VDC | 500VDC | ||||||
| PV Operate Voltage Range | 80~300VDC | 90~485VDC | ||||||
| MPPT Voltage Range | 90~260VDC | 90~450VDC | ||||||
| Battery Voltage Range | 40~60VDC | 40~58.6VDC | ||||||
| Max. PV Input Power/Current | 4500W/27A | 4500W*2/22A*2 | 4500W*2 | 9000W*2/27A*2 | ||||
| Charge Current Range (configurable) | 0~80A | 0~150A | 150A | 300A | ||||
| Max. Hybrid Charge Current (PV+AC) | ||||||||
| Max. Hybrid Charge Current (configurable) | 0~80A | 0~150A | 0~220A | |||||
| Certification | ||||||||
| Safety Certification | CE(IEC62109-1,2) | UL1741 | ||||||
| EMC Certification Level | EN61000,C2 | FCC part15,CLASS B | ||||||
| Operate Temperature Range | -15~55°C | |||||||
| Storage Temperature Range | -25~60°C | |||||||
| Humidity Range | 5~95%(Three anti-paint protection) | |||||||
| Noise | ≤60dB | |||||||
| Cooling | Forced air cooling, adjustable wind speed | |||||||
| Communicate | USB/RS485/(WiFi/GPRS)/Dry node control | |||||||
| Other | ||||||||
| Dimensions(L*W*H)mm | 280*100*415 | 350*120*540 | 580*127*359 | 450*132*620 | ||||
| Package Dimensions(L*W*H)mm | 385*200*505 | 460*230*645 | 700*252*470 | 545*230*715 | ||||
| Weight(KG) | 7.8 | 18.5 | 18.9 | 23.8 | ||||
Why We Recommend the AS Inverter

For customers supplying 120 V loads, we recommend the 3.6 kW and 6.5 kW AS models. Both combine pure sine wave output with built-in MPPT solar charging, so solar charging and AC power conversion come in one unit. They can work without a storage battery or form part of a battery-based system. That makes AS a useful choice whether the customer wants to use solar without storage or include a battery from the outset.
For customers who need 120/240 V split-phase output, we recommend the 7.2 kW and 12 kW AS models. We would choose a B version when parallel expansion is part of the plan, with support for up to six units. Optional Wi-Fi monitoring is another feature we recommend for customers who want to check operation without standing in front of the inverter.
FAQS
Which power ratings are available in the AS range?
The AS range includes 3.6 kW, 6.5 kW, 7.2 kW and 12 kW models, each offered in A and B versions. The 3.6 kW and 6.5 kW models provide 120 V output; the 7.2 kW and 12 kW models offer 120/240 V split-phase output.
What is the difference between AS A and B models?
A models are stand-alone versions. B models support parallel operation with up to six units. Both versions are available at each of the four AS power ratings.
Does the 12 kW AS deliver 12 kW in single-phase operation?
The 12 kW rating applies to split-phase output. The catalogue lists single-phase output for the AS123048-M200 models at 7200VA/7200W, limited by the wiring terminals.
Can AS operate without a battery, and what battery voltage does it use?
AS can use available solar and utility power to supply loads without a storage battery. With storage, the 3.6 kW and 6.5 kW models have a nominal 48 V battery input; the 7.2 kW and 12 kW models have a nominal 51.2 V battery input. The range supports lead-acid or lithium batteries.
Is Wi-Fi monitoring included as standard?
Wi-Fi remote monitoring is optional. The front-panel display provides local operating information, and USB and RS485 interfaces provide communication options.