SNADI AS Hybrid Solar Inverter

3.6 kW6.5 kW7.2 kW12 kW

Exterior style

3.6 kW exterior style selected
SNADI AS Hybrid Solar Inverter

Main Feature

  • Built-in 1 or 2 MPPT, model-dependent
  • Up to six units in parallel on B models
  • Off-grid and grid-connected operation
  • Battery-free operation
  • Detachable dust cover
  • Optional Wi-Fi remote monitoring
Request Quote

Product Details

AS inverter close-up with an MPPT solar-charging illustration

Built-in MPPT solar charging

Built-in solar charging uses one or two MPPT trackers, depending on the AS model.

Three AS inverters with blue connection cues above a home illustration for B-model parallel expansion

Parallel expansion on B models

AS B models support up to six inverters in parallel. Choose an A model for stand-alone operation.

Single-phase and split-phase waveform comparison illustrating the AS model output choices

120 V and split-phase choices

Choose 3.6 kW or 6.5 kW models for 120 V output, or 7.2 kW or 12 kW models for 120/240 V split-phase output.

AS inverter and wall-mounted battery in an illustrative energy-storage arrangement

Solar power with or without storage

Run on available solar and utility power without a battery, or use lead-acid or lithium storage matched to your AS model.

AS side ventilation panel with illustrative airflow and airborne dust

Detachable dust cover

The AS has a detachable dust cover and forced-air cooling. Adjustable fan speed helps manage heat.

Phone with an energy-monitoring illustration beside an AS inverter in a home setting

Optional Wi-Fi monitoring

Optional Wi-Fi lets you check operation remotely. USB and RS485 provide additional communication options.

Technical specification

Download
Multi-model technical specification for SNADI AS Hybrid Solar Inverter
MODELAS362048-M80-AAS362048-M80-BAS652048-M150-AAS652048-M150-BAS722048-M150-AAS722048-M150-BAS123048-M200-AAS123048-M200-B
Parallel Mode (function reserved)
Allow Quantity-A None/-B 1~6
Mains Mode
Nominal Input Voltage120VAC±5%120VAC(L1/N, L2/N)/240VAC(L1/L2)
Input Voltage Range(90~140VAC)±2%(85~140VAC)±2%
Frequency50/60Hz(Auto Detect)
Frequency Range47±0.3Hz~55±0.3Hz(50Hz); 57±0.3Hz~65±0.3Hz(60Hz)
Max. Efficiency>95%
Conversion Time (bypass and inverter)10ms(Typical Value)
Max. Bypass Overload Current40A60A2pole, 50A/50A(L1/L2)2P,63A/63A(L1/L2)
Inverter Mode
Output Voltage WaveformPure Sine Wave
Nominal Output Power3600VA/3600W6500VA/6500WSplit phase:7200VA Single phase:6000VASplit phase:12000VA/12000W Single phase:7200VA/7200W(limited by the wiring terminals)
Power Factor1
Nominal Output Voltage120VAC120VAC(L1/N,L2/N)/240VAC(L1/L2)
Output Frequency Range50±0.3Hz/60±0.3Hz
Max. Efficiency>91%
Overload Protection(102%<load<125%)±10%: report error, turn off the output after 5 minutes (125%<load<150%)±10%: report error, turn off the output after 10 seconds load>150%±10%: report error, turn off the output after 5 seconds(102%<load<110%)±5%: report error and turn off the output after 5 minutes (110%<load<125%)±5%: report error and turn off the output after 10 seconds load>125%±5%: report error and turn off the output after 5 seconds
Peak Power7200VA12000VASplit phase:10800VA Single phase:10800VASplit phase:18000VA Single phase:18000VA
Load Motor Capability2HP5HP4HP6HP
Nominal Battery Input Voltage48V(Min. starting voltage 44V)51.2V(Minimum starting voltage 44V)
Battery Voltage Range40.0~60Vdc±0.6Vdc(Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery...LCD screen can be set)40.0~58.6Vdc±0.6Vdc(Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery...settable on LCD screen)
Save Power ModeLoads 25W
Mains Charge
Battery TypeLead-acid or lithium batteries
Max. Charge Current (configurable)40A120A160A
Charge Voltage Range40~60VDC40~58.6VDC
Solar Charge
Max. PV Open Circuit Voltage300VDC500VDC
PV Operate Voltage Range80~300VDC90~485VDC
MPPT Voltage Range90~260VDC90~450VDC
Battery Voltage Range40~60VDC40~58.6VDC
Max. PV Input Power/Current4500W/27A4500W*2/22A*24500W*29000W*2/27A*2
Charge Current Range (configurable)0~80A0~150A150A300A
Max. Hybrid Charge Current (PV+AC)
Max. Hybrid Charge Current (configurable)0~80A0~150A0~220A
Certification
Safety CertificationCE(IEC62109-1,2)UL1741
EMC Certification LevelEN61000,C2FCC part15,CLASS B
Operate Temperature Range-15~55°C
Storage Temperature Range-25~60°C
Humidity Range5~95%(Three anti-paint protection)
Noise≤60dB
CoolingForced air cooling, adjustable wind speed
CommunicateUSB/RS485/(WiFi/GPRS)/Dry node control
Other
Dimensions(L*W*H)mm280*100*415350*120*540580*127*359450*132*620
Package Dimensions(L*W*H)mm385*200*505460*230*645700*252*470545*230*715
Weight(KG)7.818.518.923.8

SNADI AS Hybrid Solar Inverter System Configuration

SNADI AS hybrid inverter system relationshipsIllustrative system relationships for the SNADI AS family, not terminal wiring or a phase-conductor diagram. The 3.6 kW and 6.5 kW models have 120 V output; 7.2 kW and 12 kW models provide 120/240 V split-phase output with separate single-phase limits. Nominal battery input is model-dependent at 48 V or 51.2 V. Battery storage and Wi-Fi monitoring are optional, and parallel expansion applies to B models. Solid lines represent DC or AC power; dashed lines represent external communication and measurement. Gateway, cloud and metering nodes do not establish built-in accessories or verified protocols for every model. The grid-export branch is a template-level scenario, not proof of permitted grid export. Day and night flows show illustrative conditions, not a fixed operating schedule.Wi-Fi / 4G GatewaySNADI CloudPC / Mobile MonitoringPV ArrayUtility GridCT / Smart MeterSNADI AS Hybrid Solar InverterExternal Battery SystemProtected AC Loads
DC EnergyAC EnergyCommunication

Why We Recommend the AS Inverter

Illustrative portrait of a man in a white SNADI polo shirt

For customers supplying 120 V loads, we recommend the 3.6 kW and 6.5 kW AS models. Both combine pure sine wave output with built-in MPPT solar charging, so solar charging and AC power conversion come in one unit. They can work without a storage battery or form part of a battery-based system. That makes AS a useful choice whether the customer wants to use solar without storage or include a battery from the outset.

For customers who need 120/240 V split-phase output, we recommend the 7.2 kW and 12 kW AS models. We would choose a B version when parallel expansion is part of the plan, with support for up to six units. Optional Wi-Fi monitoring is another feature we recommend for customers who want to check operation without standing in front of the inverter.

FAQS

Which power ratings are available in the AS range?

The AS range includes 3.6 kW, 6.5 kW, 7.2 kW and 12 kW models, each offered in A and B versions. The 3.6 kW and 6.5 kW models provide 120 V output; the 7.2 kW and 12 kW models offer 120/240 V split-phase output.

What is the difference between AS A and B models?

A models are stand-alone versions. B models support parallel operation with up to six units. Both versions are available at each of the four AS power ratings.

Does the 12 kW AS deliver 12 kW in single-phase operation?

The 12 kW rating applies to split-phase output. The catalogue lists single-phase output for the AS123048-M200 models at 7200VA/7200W, limited by the wiring terminals.

Can AS operate without a battery, and what battery voltage does it use?

AS can use available solar and utility power to supply loads without a storage battery. With storage, the 3.6 kW and 6.5 kW models have a nominal 48 V battery input; the 7.2 kW and 12 kW models have a nominal 51.2 V battery input. The range supports lead-acid or lithium batteries.

Is Wi-Fi monitoring included as standard?

Wi-Fi remote monitoring is optional. The front-panel display provides local operating information, and USB and RS485 interfaces provide communication options.