Main Features
- Built-in 1 or 2 MPPT
- Can parallel 1-6 units
- Can operate independently off the grid or in parallel with the grid
- Capable to work without battery
- Detachable dust cover for harsh environment
- Wifi remote monitoring optional
Product Details

IP54 enclosure protection
An IP54-rated enclosure and detachable dust cover bring practical protection to the AS IP54 (US).

Integrated MPPT charging
Built-in MPPT charging brings solar power into the inverter, with one or two trackers by model.

120 V and split-phase output
Choose 3.6 or 6.5 kW for 120 V loads, or the 12 kW model for 120/240 V split-phase output.

Solar with or without storage
Use available solar and utility power without a battery, or add lead-acid or lithium storage.

Expansion on B models
B models support up to six inverters in parallel, bringing multi-unit expansion to the AS IP54 range.

Optional Wi-Fi monitoring
Optional Wi-Fi brings operating information beyond the front panel, alongside USB and RS485 interfaces.
Technical specification
Download| MODEL | AS-362048-54A | AS-362048-54B | AS-652048-54A | AS-652048-54B | AS-123048-54A | AS-123048-54B |
|---|---|---|---|---|---|---|
| Parallel Mode (function reserved) | ||||||
| Allow Quantity | -A None/-B 1~6 | |||||
| Mains Mode | ||||||
| Nominal Input Voltage | 120VAC±5% | 120VAC(L1/N, L2/N)/240VAC(L1/L2) | ||||
| Input Voltage Range | (90~140VAC)±2% | (85~140VAC)±2% | ||||
| Frequency | 50/60Hz(Auto detect) | |||||
| Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz); 57±0.3Hz~65±0.3Hz(60Hz) | |||||
| Max. Efficiency | >95% | |||||
| Conversion Time (bypass and inverter) | 10ms(Typical value) | |||||
| Max. Bypass Overload Current | 40A | 60A | 2pole, 60A/60A(L1/L2) | |||
| Inverter Mode | ||||||
| Output Voltage Waveform | Pure Sine Wave | |||||
| Nominal Output Power | 3600VA/3600W | 6500VA/6500W | Split phase:12000VA/12000W Single phase:7200VA/7200W(limited by the wiring terminals) | |||
| Power Factor | 1 | |||||
| Nominal Output Voltage | 120VAC | 120VAC(L1/N, L2/N)/240VAC(L1/L2) | ||||
| Output Frequency Range | 50±0.3Hz/60±0.3Hz | |||||
| Max. Efficiency | >91% | |||||
| Overload Protection | (102%<load<125%)±10%: report error, turn off the output after 5 minutes (125%<load<150%)±10%: report error, turn off the output after 10 seconds load>150%±10%: report error, turn off the output after 5 seconds | (105%<load<110%)±5%: report error and turn off the output after 5 minutes; (110%<load<125%)±5%: report error and turn off the output after 10 seconds; load>125%±5%: report error and turn off the output after 5 seconds; | ||||
| Peak Power | 7200VA | 12000VA | Split phase:18000VA; Single phase:18000VA | |||
| Load Motor Capability | 2HP | 5HP | 6HP | |||
| Nominal Battery Input Voltage | 48V(Min. starting voltage 44V) | 51.2V(Minimum starting voltage 44V) | ||||
| Battery Voltage Range | 40.0~60VDC±0.6VDC(Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery...LCD screen(can be set) | 40.0~58.6VDC±0.6VDC(Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery... settable on LCD screen) | ||||
| Save Power Mode | Loads 25W | Load per phase is null or less than 25W enter power-saving mode | ||||
| Mains Charge | ||||||
| Battery Type | Lead-acid or lithium batteries | |||||
| Max. Charge Current (configurable) | 40A | 120A | 160A | |||
| Charge Voltage Range | 40~60VDC | 40~58.6VDC | ||||
| Solar Charge | ||||||
| Max. PV Open Circuit Voltage | 300VDC | 500VDC | ||||
| PV Operate Voltage Range | 80~300VDC | 90~500VDC | ||||
| MPPT Voltage Range | 90~260VDC | 80~450VDC | ||||
| Battery Voltage Range | 40~60VDC | 40~58.6VDC | ||||
| Max. PV Input Power/Current | 4000W/22A | 4500W*2/22A*2 | 6000W*2 | |||
| Charge Current Range (configurable) | 0~80A | 0~150A | 220A | |||
| Max. Hybrid Charge Current (PV+AC) | ||||||
| Max. Hybrid Charge Current (configurable) | 0~80A | 0~150A | 0~220A | |||
| Certification | ||||||
| Safety Certification | CE(IEC62109-1.2) | UL1741 | ||||
| EMC Certification Level | EN61000,C2 | FCC part15, CLASS B | ||||
| Operate Temperature Range | -15~55°C | |||||
| Storage Temperature Range | -25~60°C | |||||
| Humidity Range | 5~95%(Three anti-paint protection) | |||||
| Noise | ≤60dB | |||||
| Cooling | Forced air cooling, adjustable wind speed | |||||
| Communicate | USB/RS485/(WiFi/GPRS)/Dry node control | |||||
| Other | ||||||
| External Dimensions:L*W*H(mm) | 320*110*465 | 433*135*592 | 562*137*714 | |||
| Packing Dimensions:L*W*H(mm) | 425*210*535 | 510*230*665 | 640*235*785 | |||
Why We Recommend the AS IP54 (US) Inverter

At SNADI, we recommend AS IP54 (US) for the details that make a finished inverter worth choosing. Its IP54-rated housing and detachable dust cover put enclosure protection at the forefront, while adjustable-speed forced-air cooling complements the design. Inside, built-in MPPT charging and pure sine wave output handle the core solar and power-conversion functions. For your customers, these are tangible reasons to choose our product—not just another power rating on a label.
What we like about AS IP54 (US) is how easily its strengths carry through to the customer. You can show them the enclosure and dust cover, explain how the built-in solar charging works, and offer optional Wi-Fi if they want to check operation remotely. With 3.6, 6.5 and 12 kW options, you have a range to offer rather than a single power rating. We recommend it to distributors and installers who want a product they can present with confidence and source directly from SNADI.
FAQS
Which AS IP54 (US) models provide split-phase output?
The 12 kW AS-123048-54A and AS-123048-54B provide 120/240 V split-phase output. Their single-phase output is 7200VA/7200W, limited by the wiring terminals. The 3.6 kW and 6.5 kW models provide 120 V output.
What is the difference between the A and B versions?
A versions are stand-alone models. B versions support parallel operation with up to six units. Both versions are available at 3.6 kW, 6.5 kW and 12 kW.
Can AS IP54 run without a battery?
Yes. AS IP54 can supply loads from available solar and utility power without a storage battery. For battery-based operation, the 3.6 kW and 6.5 kW models use a nominal 48 V input, while the 12 kW models use 51.2 V. Lead-acid and lithium batteries are supported.
What enclosure and cooling features does AS IP54 have?
The AS IP54 (US) has an IP54-rated enclosure and a detachable dust cover. Forced-air cooling uses adjustable fan speed.
Is Wi-Fi monitoring standard on AS IP54?
Wi-Fi remote monitoring is optional. USB and RS485 provide additional communication interfaces, and operating information is available at the front-panel display.