Main Feature
- Double MCU intelligent control
- Settable mains supply preferred mode or battery preferred mode
- Settable charge current and multiple threshold voltages
- Settable AC output voltage and frequency
- Pure sine wave output and settable unattended function
- Intelligent cooling, LCD real-time display and protection/alarm functions
Product Details

Double MCU intelligent control
Double MCU intelligent control forms part of the FT inverter's operating architecture.

Mains or battery priority
Mains supply preferred mode and battery preferred mode can be set for different operating requirements.

Adjustable charge settings
Adjustable charging current and voltage thresholds support battery selections within the FT model's limits.

Configurable AC output
Output voltage and frequency are configurable, with model-specific voltage groups and 50/60 Hz inverter operation.

Unattended operation and pure sine wave
FT combines pure sine wave output with a configurable unattended-operation function.

Cooling, LCD and protection
Intelligent cooling, an LCD status display, protection and alarms support local FT operation.
Technical specification
Download| MODEL | FT-1000 | FT-2000 | FT-3000 | FT-5000 | FT-6000 | FT-8000 | FT-10K | FT-12K |
|---|---|---|---|---|---|---|---|---|
| Rated Power | 1000W | 2000W | 3000W | 5000W | 6000W | 8000W | 10000W | 12000W |
| Battery | ||||||||
| Rated Voltage | 12/24/48VDC | 24/48VDC | 48VDC | 48/72/96VDC | 48V | |||
| Charge Current | 30A(default) -CO-C6 | |||||||
| Battery Type | U0~U7 | |||||||
| AC Input | ||||||||
| Voltage Range | 85~138/170~275VAC | 130~280VAC 160~260VAC | ||||||
| Frequency | 45~65Hz | |||||||
| AC Output | ||||||||
| Voltage Range | 100/110/120VAC 200/210/220/230/240VAC | 220/230/240VAC | 200/210/220/230/240VAC | |||||
| Frequency | 50/60Hz±1%(Inversion mode) | |||||||
| Output Wave | Pure Sine Wave | |||||||
| Conversion Time | <10ms(Typical load) | |||||||
| Efficiency | >85%(80% resistive load) | |||||||
| Overload | 110~120%/60s;120~130%/10s 130~150%/2s;>150%/500ms | |||||||
| Protection Function | Battery overvoltage protection,battery undervoltage protection,overload protection, short circuit protection,overtemperature protection,etc. | |||||||
| Ambient Temperature For Operation | 0~40°C | |||||||
| Ambient Temperature For Storage | -15~50°C | |||||||
| Operation/Storage Ambient | 0~90% No Condensation | |||||||
| Machine Size: L*W*H (mm) | 486*247*179 | 555*307*189 | 653*332*260 | 717*230*360 | ||||
| Package Size: L*W*H (mm) | 550*310*230 | 640*370*240 | 715*365*310 | 785*305*415 | ||||
Why We Recommend the FT Inverter

At SNADI, we recommend the FT for a distributor or installer building a low-frequency inverter/charger line, because the range gives you eight model steps from 1 kW to 12 kW with pure sine wave output. That breadth lets one FT family cover different off-grid power levels without forcing every application into a single wattage.
The FT puts control of charging and power priorities in your hands. Adjustable charging current and voltage settings, together with a choice of mains-first or battery-first operation, let you tailor how the inverter works with the battery bank. At SNADI, we see that flexibility as a key reason to choose the FT: customers get more control over everyday power use, with operating information clearly available on the LCD.
FAQS
Which FT model and power rating should I quote?
The 2026 catalogue lists FT-1000, FT-2000, FT-3000, FT-5000, FT-6000, FT-8000, FT-10K and FT-12K, from 1000W to 12000W. Share the target load, local AC supply and order quantity so SNADI can confirm the exact configuration.
Which battery voltage applies to my FT model?
The catalogue groups the models as follows: FT-1000/FT-2000 at 12/24/48VDC; FT-3000/FT-5000 at 24/48VDC; FT-6000 at 48VDC; FT-8000/FT-10K at 48/72/96VDC; and FT-12K at 48V. Confirm the exact battery voltage for the selected model before ordering.
Can the FT switch between mains and battery priority?
Yes, the FT manual lists settable mains supply preferred mode and battery preferred mode. It also lists settable charge current and multiple threshold voltages; ask SNADI to confirm the available settings for the selected model and battery.
What AC input and output should I confirm?
The catalogue records model-specific AC input ranges, 45~65Hz input frequency, selectable AC output groups from 100/110/120VAC and 200/210/220/230/240VAC, 50/60Hz inverter-mode operation, pure sine wave output and conversion time below 10ms under a typical load. Confirm the local supply and exact output group with SNADI before quotation.
What information should I send SNADI for a factory quotation?
Send the FT model or target power, battery voltage, local AC input and output requirements, frequency, intended loads, destination market, quantity and any installation constraints. The factory team can then confirm the configuration against the current FT documents.









